Request a Quote

  Home > BRANDS > BRK Electronics > BRK Electronics Smoke/Carbon Monoxide (CO) Alarm >

BRK Electronics First Alert SC9120LBL 120V AC/DC Hardwired with Lithium Battery Back Up and Locked Battery Drawer Ionization Smoke Alarm and Carbon Monoxide Combo Alarm
BRK Electronics First Alert SC9120LBL 120V AC/DC Hardwired with Lithium Battery Back Up and Locked Battery Drawer Ionization Smoke Alarm and Carbon Monoxide Combo Alarm


 
Our Price: $41.38
Request Large Quantity Quote




Model: BRK-SC9120LBL
Qty:

Technical Spec Downloads
 
Technical Spec
120V AC/DC Ionization Smoke/CO Alarm with a 10YR Lithium Battery Back-up. The battery drawer is shipped pre-locked so battery will not be discarded prematurely. Under normal conditions you should not have to replace the battery for the life of the alarm.
  • 10YR Lithium Battery Backup
  • Locked Battery Drawer
  • Electrochemical Carbon Monoxide Sensor - the most accurate sensor available as compared to other sensing technologies
  • Latching alarm indicator - remembers which unit initiated an alarm
  • Intelligent Sensing TechnologyTM helps reduce the number of nuisance alarms
  • Perfect Mount - allows for easy alignment of alarm
  • Single button test/silence
  • Easy Installation/Maintenance - Preferred features include a large opening in the mounting bracket for easy access to wiring. Keyhole slots in the mounting bracket eliminate the need to remove the electrical box screws for installation. A battery pull tab keeps the battery fresh until the home is occupied. Battery installation and removal can occur while the unit is mounted to the ceiling or wall via the side load battery compartment. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a "Quick-Connect" wiring harness. Installation is quick, easy and cost effective.
  • Dust Cover
  • 10-Years Limited Warranty

Model: SC9120LBL
Alarm Dimensions:
5.6”dia. x 2.0”H
Weight: 8.5 oz
Operating Voltage:
120V AC 60Hz w/ 9V lithium battery backup
Operating Current: 0.09 amps (standby/alarm)
Temperature Range:
40°F (4°C) to 100°F (38°C)
Humidity Range:
10% to 95% relative humidity (RH)
Audio Alarm:
85dB at 10 feet
Test/Silence:
Electronically simulates smoke or CO condition, causing the unit to alarm. Press and hold test/silence button.
Alarm Reset:
Automatic when smoke or CO clears
Interconnections: Up to 18 units of First Alert or BRK Smoke, CO and Heat Alarms. Maximum of 12 smoke alarms. See user’s manual for details.
Smoke Sensor: Dual Ionization
CO Sensor:
Electrochemical
Indicator Lights/Sounds: AC Power: Constant Green LED
DC Power: Intermittent Green LED
Local Alarm: Red LED flashes rapidly
Remote Alarm: Red LED out.
Latching Alarm: Red LED flashes 2 sec. on/2 sec. off after local alarm
Low Battery Latch: Green LED flashes on for 2 seconds, off for 2 seconds.
Listing:
Listed to UL217 and UL2034 Standards

Share your knowledge of this product. Be the first to write a review »

Browse for more products in the same category as this item: